Troubleshooting
Symptom-indexed troubleshooting guide for startup, ports, OBS, CTS timing, imports, licensing, AI commentary, and diving.
Find your symptom below to see the cause, fix, and related manual section.
Startup, ports, and Windows #
Windows SmartScreen blocks LaneCue.exe #
- Cause: Direct-distributed Windows executable without an EV certificate prompt bypass.
- Fix: Click More info → Run anyway. See Getting started.
App won't start or closes immediately #
- Cause: Startup error, corrupt config, or port conflict.
- Fix: Open
lanecue.login the same folder asLaneCue.exeto read the exact error, or launch from PowerShell to view console output. See Getting started.
Port 4780 is already in use (EADDRINUSE) #
- Cause: Another process (or an already-running LaneCue instance) is bound to port
4780. - Fix: Close the existing instance, or change the port in Settings → 🌐 Server & Port,
lanecue.config.json,LANECUE_PORT, or--port <number>. See Getting started.
OBS Browser Sources stopped working after a port change #
- Cause: OBS Browser Sources still point to the old port (
http://localhost:4780/overlay/…). - Fix: Update every Browser Source URL in OBS to match the new port and refresh the sources. See OBS setup.
Browser did not open automatically on launch #
- Cause:
--no-openwas passed,"openBrowser": falseis set inlanecue.config.json, or Windows has no default browser association. - Fix: Open Chrome or Edge manually and browse to
http://localhost:4780.
OBS Studio and overlays #
OBS won't connect (OBS: DISCONNECTED) #
- Cause:
obs-websocketv5 is disabled, wrong port (default4455), or password mismatch. - Fix: In OBS Tools → WebSocket Server Settings, enable the server, verify port
4455, copy the password into Connections → 🎥 OBS Broadcast, and click Test & Save. See OBS setup.
Overlay is blank or shows "No Active Meet" #
- Cause: No meet is activated, Browser Source dimensions are not
1920×1080, or the layer is toggled off in the current scene preset. - Fix: Select an active meet in the top bar dropdown, set OBS Browser Source size to
1920×1080, and check layer toggles in Live Director. See OBS setup.
Scenes do not switch automatically #
- Cause:
HOLDis active,AUTOis disabled, or scene names are not mapped to scene roles. - Fix: Press H to release Hold, confirm
AUTOis active, and verify role mappings in Connections → 🎥 OBS Broadcast. See Running a meet.
Overlay layers appear in the wrong front-to-back order #
- Cause: Composite
/overlay/programstacking order needs adjustment. - Fix: Drag and drop or use
↑/↓in Connections → 🎥 OBS Broadcast (or click Reset Order). See OBS setup.
Instant Replay does nothing #
- Cause: OBS Replay Buffer is disabled or no
REPLAYscene is mapped. - Fix: Enable Replay Buffer in OBS Settings → Output and map a
REPLAYscene in Connections → 🎥 OBS Broadcast. See OBS setup.
Timing (CTS) and pool calibration #
CTS shows no data (CTS: DISCONNECTED or CONNECTED_IDLE) #
- Cause: Wrong COM port, baud/framing mismatch, or wrong cable/adapter.
- Fix: Verify System 5/6 uses
9600 8E1and Gen7 uses115200 8N1, check Device Manager for the COM port, and watch the Live CTS Inspector in Connections → ⏱️ Timing Console (CTS). See Timing (CTS) setup.
CTS MISMATCH warning in the top bar #
- Cause: The timing console is on a different event/heat than the Operator UI.
- Fix: Click [Sync] on the yellow pill to jump to the console's heat, or [Ignore] to keep your current view. See Timing (CTS) setup.
Lanes appear in reverse order or shifted on camera #
- Cause: Pool profile lane numbering (
1..NvsN..1) or 4-corner calibration doesn't match the camera angle. - Fix: Open Pool Calibration, verify lane order and
startSide, and re-drag the 4 corners over a fresh test frame. See Camera & pool calibration.
Imports and data #
Swimmer or team names look garbled #
- Cause: Legacy Hy-Tek files use Windows-1252 encoding.
- Fix: Re-import the original
.hy3/.mdbfile without re-saving it in a text editor as a different encoding. See Preparing a meet.
PDF import misses heats or columns; .mdb import fails #
- Cause: Unusual PDF layout or corrupted/unsupported
.mdbfile. - Fix: On paid tiers, enable BYOK Gemini PDF fallback; for
.mdb, ensure the file is a valid Hy-Tek Jet 4.0 database. See Preparing a meet.
Licensing and activation #
DEMO LIMIT REACHED or locked heats (🔒) #
- Cause: Running in the free Demo tier, which caps meets at 3 events / 15 heats.
- Fix: Activate a paid license key in Settings → 🔑 License. See Licensing & activation.
LEASE_LAPSED, EXPIRED, NOT_YET_VALID, MACHINE_MISMATCH, or clock warning #
- Cause: 30-day offline lease lapsed, term ended, system clock is off by > 15 minutes, or lease belongs to another laptop.
- Fix: Connect to the internet to renew (
LEASE_LAPSED), sync Windows time (NOT_YET_VALID/ clock warning), or release the seat on the previous laptop (MACHINE_MISMATCH). See Licensing & activation.
Online activation fails #
- Cause: No internet connection, captive portal Wi-Fi, or firewall blocking
https://api.getlanecue.com. - Fix: Confirm browser access to
https://api.getlanecue.com/v1/healthand retry activation.
AI commentary and diving #
403 LICENSE_REQUIRED or 🔒 AI: DEMO #
- Cause: AI features (Live AI Commentary, Gemini PDF fallback, diving paper-sheet OCR) are disabled in the free Demo tier.
- Fix: Activate a paid license and enter your own Gemini API key in Connections → 🎙️ Live AI Commentary. See AI commentary.
AI commentary is silent, or AI voice leaks into the stream #
- Cause: Wrong audio output device, Starter Hold (Space) active, or OBS is capturing desktop audio that includes the AI output bus.
- Fix: Select your headphones or dedicated Voicemeeter bus in Connections → 🎙️ Live AI Commentary, and exclude that bus from OBS stream tracks. Captions missing? Check
/overlay/captionsor thecaptionslayer in/overlay/program. See AI commentary.
Dive-sheet warnings or 409 score overwrite prompt #
- Cause: A dive violates a rule profile check (e.g., DD cap or group count) or you are re-scoring an already-scored round.
- Fix: Use Allow (EXH) for exhibition overrides, or confirm the overwrite dialog when correcting a round score. See Diving.
Collecting diagnostics for support #
Before contacting support via Help & About or the Support form:
- Open Help & About and click Copy Diagnostics (includes app version, Machine ID, and license state).
- Attach
lanecue.logif reporting a crash or connection error. - Never send your raw
LC-…license key or your Google Gemini API key.